Keg cooler defrost and controller repair — cidery, Longmont

A cidery in Longmont called because its keg cooler was not holding temperature. The controller was reading 50°F and the evaporator was covered in ice.

Equipment: Walk-in keg cooler with a Bohn evaporator and Johnson Controls temperature control; True prep table

Bohn evaporator in the keg cooler

The problem

A keg cooler that runs warm affects every tap line at once, so a cidery loses product quality fast.

Ice on the evaporator coil blocks airflow. The unit can run all day and still not cool the box, and the cause is usually in the defrost system or its controls rather than the compressor.

What we did

  1. Inspected the iced Bohn evaporator and its defrost controls and wiring.
  2. Repaired the defrost issue.
  3. Replaced the temperature controller.
  4. Cleaned the evaporator drain hose so melt water drains properly.
  5. Checked the True prep table on site with an infrared thermometer.
Photos from the job

On site

Result

After the repair the controller read 32°F and the keg cooler held temperature.

Takeaway for operators

Ice on a cooler evaporator is a symptom, not the fault. Fixing the defrost and drain is what keeps it from icing up again.