Electronic refrigeration controllers (Dixell, now Copeland/Emerson) used on many reach-in coolers, freezers and walk-ins. Covers: XR06CX and XR60CX (other XR models use similar but not identical code sets)

Commercial service call$129
Waived when you approve the repairWritten quote before any work · same- or next-day appointments · 90-day warranty on parts and labor

How the codes appear

The alarm code is shown on the controller's display in place of / alternating with the temperature reading.

Resetting

Probe alarms (P1-P4) clear a few seconds after the probe reads normally again. HA/LA/HA2/LA2 clear automatically when temperature returns to normal. EA and CA (serious alarm) clear when the digital input is no longer active. On the XR60CX, CA caused by the pressure switch setting only clears by switching the controller off and on.

If the same code comes back after a reset, stop resetting it — repeated restarts can hide the real fault or damage components. Call a technician.

Dixell code list

P1

Room (thermostat) probe failure

Technician

The controller has lost a valid reading from the cabinet/room air probe. The compressor then runs on a fixed on/off timing set by parameters instead of by temperature.

Causes the manufacturer lists

  • Faulty probe or probe connection (manual says check connections before replacing the probe)

What staff can safely check

  • Note the code and whether product is holding temperature; use a separate thermometer to check the box
P2

Evaporator probe failure

Technician

The evaporator (defrost) probe is not reading correctly. Defrost will end on time instead of on temperature.

Causes the manufacturer lists

  • Faulty probe or probe connection (manual says check connections before replacing the probe)

What staff can safely check

  • Watch for heavy ice on the evaporator coil and report it
P3

Third probe failure

Technician

The optional third probe is not reading correctly (XR60CX). Outputs are not changed.

Causes the manufacturer lists

  • Faulty probe or probe connection
P4

Fourth probe failure

Technician

The optional fourth probe is not reading correctly (XR60CX). Outputs are not changed.

Causes the manufacturer lists

  • Faulty probe or probe connection
HA

Maximum temperature alarm

Status / staff can check

The box temperature has gone above the high alarm limit. The controller keeps running normally; this is a warning.

What staff can safely check

  • Make sure the door is fully closed and the gasket seals
  • Check that air vents/fans inside are not blocked by product
  • Move product to another unit if temperature keeps rising
LA

Minimum temperature alarm

Status / staff can check

The box temperature has dropped below the low alarm limit. The controller keeps running normally; this is a warning.

What staff can safely check

  • Check the box with a separate thermometer and protect product from freezing
HA2

Condenser high temperature alarm

Technician

The condenser temperature is too high (XR60CX, when a condenser probe is used). Whether the compressor is stopped depends on a parameter setting.

What staff can safely check

  • Make sure nothing is blocking airflow around the condensing unit
LA2

Condenser low temperature alarm

Technician

The condenser temperature is too low (XR60CX, when a condenser probe is used).

dA

Door open alarm

Status / staff can check

The door switch has reported the door open too long. The compressor and fans are restarted.

Causes the manufacturer lists

  • Door left open

What staff can safely check

  • Close the door fully and check nothing is propping it open
EA

External alarm

Technician

An external device wired to the controller's digital input is signalling an alarm. Outputs are not changed.

CA

Serious external alarm / pressure switch alarm

Technician

A serious external alarm (or, on XR60CX, a pressure switch alarm) has been signalled on the digital input. All outputs are switched off, so the unit stops cooling.

What staff can safely check

  • Move product to working refrigeration

Seeing Dixell codes you can't clear?

Same- or next-day appointments across the Denver metro. Written quote before any work, EPA 608 certified technicians.

Request service

Model notes

P3, P4, HA2, LA2 are listed only in the XR60CX manual. Exact code list varies by Dixell model; equipment makers may also set parameters differently. Other display messages (not alarms): Pon/PoF keyboard unlocked/locked, noP probe not enabled, noA no alarm recorded.

Sources

Compiled and paraphrased from the manufacturer documents above. Codes differ between model years and control boards — confirm against the manual for your exact model. ABC Denver Appliance Repair is an independent service company, not affiliated with Dixell.

From our job records

Photos from our job records

Real photos our technicians took on calls around Denver and the Front Range. Each caption says what was done; no customer details are shown.

Door latch area on a Whirlpool combo that wouldn't stay shut
Door latch area on a Whirlpool combo that wouldn't stay shut
LG freezer evaporator checked on a compressor diagnosis, Lochbuie
LG freezer evaporator checked on a compressor diagnosis, Lochbuie
Baker's Pride gas pizza oven in a Lakewood restaurant after a thermostat replacement
Baker's Pride gas pizza oven in a Lakewood restaurant after a thermostat replacement
Maytag electric range in Westminster after a bake element replacement
Maytag electric range in Westminster after a bake element replacement

Call (720) 534-0432