P1
Room (thermostat) probe failure
Technician The controller has lost a valid reading from the cabinet/room air probe. The compressor then runs on a fixed on/off timing set by parameters instead of by temperature.
Causes the manufacturer lists
- Faulty probe or probe connection (manual says check connections before replacing the probe)
What staff can safely check
- Note the code and whether product is holding temperature; use a separate thermometer to check the box
P2
Evaporator probe failure
Technician The evaporator (defrost) probe is not reading correctly. Defrost will end on time instead of on temperature.
Causes the manufacturer lists
- Faulty probe or probe connection (manual says check connections before replacing the probe)
What staff can safely check
- Watch for heavy ice on the evaporator coil and report it
P3
Third probe failure
Technician The optional third probe is not reading correctly (XR60CX). Outputs are not changed.
Causes the manufacturer lists
- Faulty probe or probe connection
P4
Fourth probe failure
Technician The optional fourth probe is not reading correctly (XR60CX). Outputs are not changed.
Causes the manufacturer lists
- Faulty probe or probe connection
HA
Maximum temperature alarm
Status / staff can check The box temperature has gone above the high alarm limit. The controller keeps running normally; this is a warning.
What staff can safely check
- Make sure the door is fully closed and the gasket seals
- Check that air vents/fans inside are not blocked by product
- Move product to another unit if temperature keeps rising
LA
Minimum temperature alarm
Status / staff can check The box temperature has dropped below the low alarm limit. The controller keeps running normally; this is a warning.
What staff can safely check
- Check the box with a separate thermometer and protect product from freezing
HA2
Condenser high temperature alarm
Technician The condenser temperature is too high (XR60CX, when a condenser probe is used). Whether the compressor is stopped depends on a parameter setting.
What staff can safely check
- Make sure nothing is blocking airflow around the condensing unit
LA2
Condenser low temperature alarm
Technician The condenser temperature is too low (XR60CX, when a condenser probe is used).
dA
Door open alarm
Status / staff can check The door switch has reported the door open too long. The compressor and fans are restarted.
Causes the manufacturer lists
What staff can safely check
- Close the door fully and check nothing is propping it open
EA
External alarm
Technician An external device wired to the controller's digital input is signalling an alarm. Outputs are not changed.
CA
Serious external alarm / pressure switch alarm
Technician A serious external alarm (or, on XR60CX, a pressure switch alarm) has been signalled on the digital input. All outputs are switched off, so the unit stops cooling.
What staff can safely check
- Move product to working refrigeration