Manitowoc Indigo Ice Machine Error Codes

Indigo Series cube ice machines (air, water and remote condenser, incl. QuietQube). Covers: Indigo Series touch/display controller (event log codes E01-E34). Indigo NXT specific code list NOT verified.

Commercial service call$129
Waived when you approve the repairWritten quote before any work · same- or next-day appointments · 90-day warranty on parts and labor

How the codes appear

Faults appear as alerts on the front display home screen and are recorded with date, time and number of occurrences in the Event Log (Menu > Service > Event Log > View ELog) as E-numbered event codes.

Resetting

Alerts: from the home screen press the Left arrow to list alerts, highlight one with the Down arrow, press the Checkmark to see date/time/occurrences and possible causes, then press the Checkmark on the clear line. Event log: Menu > Service > Event Log > Clear ELog > Checkmark. (The handbook pages reviewed do not describe a separate safety-limit restart procedure.)

If the same code comes back after a reset, stop resetting it — repeated restarts can hide the real fault or damage components. Call a technician.

Manitowoc code list

E01

Long freeze cycle

Technician

Freeze cycles are running too long. Repeated long freezes trip Safety Limit #1 (on firmware 5.010 and later: freeze longer than 35 minutes for 6 freeze cycles in a row).

Causes the manufacturer lists

  • Improper installation
  • Water pressure too low (under 20 psig) or too high (over 80 psig)
  • Incoming water warmer than 90°F
  • Dirty or defective water level probe, fill valve or dump valve
  • Clogged water distribution tube
  • Water pump defect or water loss from the sump
  • Low incoming voltage
  • Ice thickness probe out of adjustment
  • Restricted airflow or dirty condenser fins, high inlet air temperature, or condenser discharge air recirculating
  • Refrigeration faults (charge, head pressure control, harvest valve, TXV, compressor, non-condensables, restrictions)

What staff can safely check

  • Make sure the water supply to the machine has not been shut off
  • Keep the air path to the condenser clear and make sure hot discharge air is not blowing back into the machine
E02

Long harvest cycle

Technician

Harvest cycles are running too long. Repeated long harvests trip Safety Limit #2 (on firmware 5.010 and later: harvest longer than 7 minutes for 3 harvest cycles in a row).

Causes the manufacturer lists

  • Improper installation
  • Dirty evaporator
  • Dirty or defective water dump valve
  • Missing vent tube on the water outlet drain
  • Water freezing behind the evaporator
  • Loose plastic extrusions or gaskets
  • Clogged water distribution tube
  • Ice thickness probe out of adjustment
  • Bin switch closed or defective
  • Premature harvest from water level probe circuit
  • Refrigeration faults (charge, head pressure control valve, harvest valve, TXV flooding, fan cycling control, water regulating valve on water-cooled units)
E03

Input power loss

Status / staff can check

The controller recorded a loss of incoming power.

E04

High condenser temperature

Technician

The condenser temperature reading went too high.

E05

High pressure control opened

Technician

The high-pressure safety switch opened.

E07

Starving TXV or low on charge

Technician

The controller detected a refrigeration pattern consistent with a starving expansion valve or low refrigerant charge (single evaporator).

E08

TXV fault

Technician

Expansion valve fault detected (single or dual circuit).

E09

#1 evaporator flooding

Technician

Evaporator #1 is flooding with refrigerant.

E10

#2 evaporator flooding

Technician

Evaporator #2 is flooding with refrigerant (dual-circuit machines).

E11

Refrigeration fault

Technician

A general refrigeration system fault was detected.

E12

Curtain switch fault

Technician

A water curtain switch stayed open too long (12 hours on E boards; 24 hours on G boards after firmware 4.017).

E15

Fan cycle control fault

Technician

Fan cycling control fault, indicated by a low liquid line temperature.

E16

Remote condensing unit fault

Technician

Fault with the remote condensing unit (ICVD / QuietQube models only).

E19

Ice thickness probe fault

Technician

The ice thickness probe circuit is faulty.

E20

Water system fault

Technician

A fault was detected in the water system.

E21

T1 temperature sensor issue

Technician

Problem with temperature sensor T1.

E22

T2 temperature sensor issue

Technician

Problem with temperature sensor T2.

E23

T3 temperature sensor issue

Technician

Problem with temperature sensor T3.

E24

T4 temperature sensor issue

Technician

Problem with temperature sensor T4.

E25

Bin level probe low sensor fault

Technician

Fault in the low sensor of the bin level probe.

E26

Bin level probe medium sensor fault

Technician

Fault in the medium sensor of the bin level probe.

E27

Bin level probe high sensor fault

Technician

Fault in the high sensor of the bin level probe.

E28

AuCS

Technician

Event related to the AuCS automatic cleaning system (the handbook gives no further description).

E29

USB communication fault

Technician

Communication fault with the USB port.

E30

USB download fault

Technician

A download through the USB port failed.

E31

Safe mode

Technician

The controller entered its safe operation mode.

E32

RS485 communication fault

Technician

Internal RS485 communication fault between controller components.

E33

Keyboard fault

Technician

Fault with the front keypad.

E34

Display fault

Technician

Fault with the display.

Seeing Manitowoc codes you can't clear?

Same- or next-day appointments across the Denver metro. Written quote before any work, EPA 608 certified technicians.

Request service

Model notes

E06, E13, E14, E17 and E18 are listed as 'spare' (unused). Safety limit timings differ by firmware (older firmware 5.09 and below: SL#1 = freeze over 60 min for 6 cycles; SL#2 = harvest over 3.5 min for 500 cycles). The handbook gives meanings only as short descriptions for most E-codes; causes are listed only for the two safety limits. The Indigo NXT (current) manual on manitowocice.com could not be fetched (site blocks automated access), so NXT-specific codes/wording are unverified and should not be assumed identical. Source is a manualslib-hosted copy of the Manitowoc handbook, not manitowocice.com directly.

Sources

Compiled and paraphrased from the manufacturer documents above. Codes differ between model years and control boards — confirm against the manual for your exact model. ABC Denver Appliance Repair is an independent service company, not affiliated with Manitowoc.

From our job records

Photos from our job records

Real photos our technicians took on calls around Denver and the Front Range. Each caption says what was done; no customer details are shown.

Denver dishwasher after a drain pump replacement
Denver dishwasher after a drain pump replacement
Front-load laundry pair on a Mead service call
Front-load laundry pair on a Mead service call
Scotsman ice machine in Broomfield after its yearly deep cleaning and descaling
Scotsman ice machine in Broomfield after its yearly deep cleaning and descaling
Thermador rangetop with griddle in Arvada after a griddle thermostat repair
Thermador rangetop with griddle in Arvada after a griddle thermostat repair

Call (720) 534-0432