Max freeze / max harvest
TechnicianThe freeze cycle exceeded 1 hour and/or harvest exceeded its maximum time. Max freeze under this code applies to pre-2106 boards only.
Home / Error codes / Ice-O-Matic
Ice machines · 7 codesElevation Series CIM modular and self-contained cubers (CIM0320-CIM2046). Covers: CIM control board (incl. board 9101414-01 Rev B and later; some codes differ on pre-2106 boards)
Errors are shown by flash patterns of the red POWER LED, and for some codes the yellow CLEAN LED as well (quick flashing, double flashes, or triple flashes followed by a pause).
Press and hold the POWER and CLEAN buttons together for 3 seconds; a single blue/yellow flash confirms that error codes and counters are cleared.
If the same code comes back after a reset, stop resetting it — repeated restarts can hide the real fault or damage components. Call a technician.
The freeze cycle exceeded 1 hour and/or harvest exceeded its maximum time. Max freeze under this code applies to pre-2106 boards only.
The board detected a failed temperature thermistor.
The water fill took longer than 5 minutes during production (on pre-2106 boards this code also covers max purge).
What staff can safely check
The water purge (drain) took longer than 2 minutes.
Harvest ran longer than the 7.5 minute maximum.
Both the 1 hour freeze limit and the 7.5 minute harvest limit were exceeded.
After the water pump started, the high float switch did not close (water level did not drop as expected). The board cycles the pump, and if the float still does not close it shuts the machine off to avoid running the evaporator without water.
Causes the manufacturer lists
Same- or next-day appointments across the Denver metro. Written quote before any work, EPA 608 certified technicians.
The 2025 manual's table lists max harvest as 5.5 min under Error 1 but 7.5 min under Error 5 and the timing table (pre-2106 boards used a 5 min max harvest); avoid quoting an exact harvest time for Error 1. Diagnostic mode is entered by holding POWER and CLEAN for 6 seconds. Per-code causes are only published for Error 7. Manual's general owner items: dedicated circuit (no GFI), 20-80 psi water at 40-100°F, water filter installed, 6 in. clearance at rear/top/sides for air-cooled units, ambient 50-100°F.
Compiled and paraphrased from the manufacturer documents above. Codes differ between model years and control boards — confirm against the manual for your exact model. ABC Denver Appliance Repair is an independent service company, not affiliated with Ice-O-Matic.
Real photos our technicians took on calls around Denver and the Front Range. Each caption says what was done; no customer details are shown.