EE
Booster not up to temperature
Technician The booster heater did not reach temperature within 8 minutes after the initial fill; may mean a booster heater failure.
Causes the manufacturer lists
What staff can safely check
- Press OFF, wait 5 seconds, press ON
E2
Fill timeout
Status / staff can check Water did not reach the float within 2.5 minutes during fill.
Causes the manufacturer lists
- Hot water supply valve closed
- Clogged line strainer
- Debris at standpipe
- Drain O-ring problem
What staff can safely check
- Make sure the hot water supply valve is open
- Check the standpipe is seated and free of debris
- Press OFF, wait 5 seconds, press ON
Ed
Possible slow leak
Status / staff can check The machine suspects a slow leak from the tank.
Causes the manufacturer lists
- Drain lever not closed
- Standpipe not seated
- Debris on drain O-ring
What staff can safely check
- Close the drain lever
- Seat the standpipe and clear debris from the O-ring
E6
Possible fault
Technician Manual says to contact Hobart service; no cause given.
P1 / P2 / P3 (with wrench light)
Possible fault
Technician Manual says to contact Hobart service; no cause given.